On-Grid PV Inverter 3500W/5000W
On-Grid PV Inverter3500W/5000W
The photovoltaic (PV) grid inverter is the coreequipment in the PV grid power station. It has high reliability, efficiency and security. It has a direct bearing on the power capacityof the power station and operation.
The solar PV grid power system is composed of PV modules,metering device, grid inverter and distribution system. The PV module transforms solar energy into DCpower and the grid inverter transforms DC power into sine wave current with thesame frequency and same phase of electricity grid and puts it into anelectricity grid.
This system is the developing trend of solar PV power,which is the most attractive energy utilization technology in 21stcentury. It is able to put energydirectly into the electricity grid without an energy storage battery. It allows full use of electric power fromrenewable energy, decreasing the energy loss and reducing the cost ofsystem. It uses both mains power andrenewable energy as power supply for the AC load, thereby reducing the loadpower shortage rate of the entire system. The renewable energy grid system is used for peak modulation against thepublic electricity grid.
Features
1. Thisproduct is a home appliance small-sized PV station and could be used in series.
3. Outdoor waterproof design IP65
4. It has a wide range of operating temperaturefrom
6. Islanding protection is available.
7. Inline waterproof block.
8. Both RS485 and USB communication port areallowed.
9. It complies with Germany VDE
Specifications
Model | EA3KLPV | EA5KLPV |
Input (DC) |
|
|
Max DC Power | 3850Wp | 5500Wp |
Max DC Voltage | 520V | 520V |
Start Voltage | 150V | 150V |
Nominal DC Voltage | 360V | 360V |
Max DC Current | 20A | 20A |
Full-Load MPP Voltage Range | 200~420V | 260~420V |
Number of MPP-Trackers | 1 | 2 |
MPPT Efficiency (Static) | >99% | >99% |
Max Input Current | 19A | 20A |
Insulation Voltage | Basic insulation 3000Vdc / 1 min | Basic insulation 3000Vdc / 1 min |
Output (AC) |
|
|
Nominal AC Power | 3500W | 5000W |
Nominal AC Voltage | 230Vac | 230Vac |
AC Voltage Range | 180Vac~260Vac | 180Vac~260Vac |
Nominal AC Current | 15A | 22A |
Nominal Frequency | 50Hz/60Hz | 50Hz/60Hz |
Frequency Tolerance Range | 47~51.5Hz / 57~61.5Hz | 47~51.5Hz / 57~61.5Hz |
Distortion (THD%) | <3% (at nominal power) | |
DC Current Component | <75mA | <110mA |
Power Factor (cos phi) | >0.99 | >0.99 |
Insulation Voltage | Basic insulation 3000Vdc / 1 min | |
Number of Grid Phases | 1 | 1 |
Efficiency |
| |
Max Efficiency | 97.3% | 97.3% |
Euro Efficiency | 96.2% | 96.5% |
General Requirements |
| |
Standby Consumption | 12W | 12W |
Night Consumption | 0W | 0W |
Topology | Transformerless | Transformerless |
Mean Time Between Failure (MTBF) | 40,000h | 40,000h |
Standard Warranty | 20 years | 20 years |
Protection |
| |
Reverse Protection (Input) | Yes | Yes |
Short-Circuit Protection (Input/Output) | Yes | Yes |
Overload Protection (Output) | Yes | Yes |
Under Voltage / Over Voltage Protection Point (Grid) | 160Vac/276Vac | 160Vac/276Vac |
Under Voltage / Over Voltage Protection Point (DC) | 120V/550V | 120V/550V |
Under Frequency / Over Frequency Protection Point (Grid) | 52Hz/ 46.5Hz; 62Hz/ 56.5Hz | |
Leakage Current Protection | DIN VDE 0126-1-1 | |
Fault Current Protection | ||
Anti-Islanding Protection | ||
Standards and Guidelines |
|
|
Certificates | TUV,CE, DIN VDE0126-1-1, comply with the DK5940 | |
EMC | EN61000-6-1, EN61000-1-2, EN61000-6-3, EN61000-1-4 / Class B | |
Safety and Regulatory | IEC 62109-1 | |
Other |
|
|
Dimensions(L×H×W) | 390 mm×480 mm ×200mm | |
Weight | 25kg | 30kg |
Acoustic Noise Level | 50dB(A) | 50dB(A) |
Operation Temperature Range | -20℃~ 60℃ (>45℃ de-rating) | |
Relative Humidity | 0~90 % | 0~90 % |
Protection Type Compliant with EN 60529 | IP65 | IP65 |
EAST is an on-grid PV inverter manufacturer, based in