Our fireproof aluminum composite panel is made of fireproof plastic core with two layers of aluminum sheets. This new decorative material comes with B1 fireproof grade according to GB8624 test. It is green material, as there is no harmful gas during burning.

Specification of Fireproof Aluminum Composite Panel
Panel thickness 3mm,4mm.5mm,6mm
Panel width 1000mm,1220mm,1250mm,1350mm,1500mm,1570mm
Panel length 2440mm-5800mm,or per customer’s request
Alu. skin thickness 0.15mm,0.21mm,0.30mm,0.40mm, 0.50mm
Standard size 1220(W) ×2440(L)mm
Paint Polyester coating
Core Fireproof- PE core
Feature
  • Fire resistant
    The outer aluminum sheet and inner fire resistant polyethylene makes the aluminum composite panel has an excellent fireproof performance. The fireproof composite material meets the GB8624 B1 standard and is fire retardant stratified, smoke less and no harmful gas.
  • High strength
    The fire resisting ACP uses high quality aluminum with greatly enhanced strength, ensure the performance of wind-pressure resistance, shockproof, and impact resistance.
  • Smooth Surface
    The fire resistant aluminium composite panel provide superior and smooth surface, satisfying the modern building with perfect appearance.
  • Easy Processing
    The fireproof ACP is easy to cut, slot, punch, bend into circular, rectangular and other shapes and also can be designed to various modeling according to your ideas.
  • Exertion Design
    The fire proof composite panel has series of gloss and shape to meet the designer’s great originality, achieve perfect results.
Fireproof ACP Structure
Compare with normal ACP

Burning test report
No Test item Test method Technical index result
1 Minimum remaining length of combustion, mm GB/T8625-88 >0 486
2 Average remaining length of combustion, mm GB/T8625-88 ≥150 163
3 Smoke temperature ℃ GB/T8625-88 ≤200 78
4 Height of fire, mm GB/T8625-88 ≤150 10
5 Grade of smoke density GB/T8627-88 <75 9
The contrast of fire-resist grade in different countries
Standard Burning Degree China Germany U.S.A France U.K Japan Russian
GB/T8627 DIN 4102 ASTM E84 BS 476 NFF 16-101 JIS K6911 30244-94
Few A A1,A2 NC 0 MO 1 T1
Minor B1 B1 A 1 M1,M2 2 T2
Normal B2 B2 B,C 2.3 M3 3 T3
Serious B3 B3 4 M4,M5